REVERSE-MORTGAGES.INFO

Jensen not updating vtp cisco for words!

Hi

 

I am currently working through some of the exercises in INE's workbook 1. I'm on VTP exercises now and have the same lab setup as the INE lab setup exactly.

I am completing exercise 1.9 - VTP transparent with switch 2 as server, switch 1 as transparent and switches 3 & 4 as client. VTP version 2 is running, there is no pruning enabled.

Trunks are working as per the lab config i.e switch one has 3 trunks to each of the other switches but the other switches do not have trunking directly to any other switch but switch 1.

Switch 4 is not updating correctly when vlan is updated on Switch 2. Switch 3 is updating correctly.

When swtich 1 is client, updates are correctly made to all switches including switch 4. 

i notice the MD5 digest on switch 4 is not matching all others, but this doesnt affect anything when switch 1 is not trasparent so im not sure this is a problem? (Passwords match also)

 

Any help much appreciated!

 

Thanks.

 

Rack1SW1#show vtp status 

VTP Version                     : running VTP2

Configuration Revision          : 0

Maximum VLANs supported locally : 1005

Number of existing VLANs        : 16

VTP Operating Mode              : Transparent

VTP Domain Name                 : CCIE

VTP Pruning Mode                : Disabled

VTP V2 Mode                     : Enabled

VTP Traps Generation            : Disabled

MD5 digest                      : 0x45 0x38 0x3B 0xB5 0xFC 0x7D 0x89 0x43 

Configuration last modified by 172.25.140.220 at 3-1-93 03:21:32

 

Rack1SW2#show vtp status 

VTP Version                     : running VTP2

Configuration Revision          : 11

Maximum VLANs supported locally : 1005

Number of existing VLANs        : 17

VTP Operating Mode              : Server

VTP Domain Name                 : CCIE

VTP Pruning Mode                : Disabled

VTP V2 Mode                     : Enabled

VTP Traps Generation            : Disabled

MD5 digest                      : 0x68 0x0B 0x63 0x90 0x52 0xAD 0x7E 0x79 

Configuration last modified by 172.25.140.220 at 3-1-93 03:23:27

Local updater ID is 172.25.140.220 on interface Vl1 (lowest numbered VLAN interface found)

 

 

Rack1SW3#show vtp status 

VTP Version                     : 2

Configuration Revision          : 11

Maximum VLANs supported locally : 1005

Number of existing VLANs        : 17

VTP Operating Mode              : Client

VTP Domain Name                 : CCIE

VTP Pruning Mode                : Disabled

VTP V2 Mode                     : Enabled

VTP Traps Generation            : Disabled

MD5 digest                      : 0x68 0x0B 0x63 0x90 0x52 0xAD 0x7E 0x79 

Configuration last modified by 172.25.140.220 at 3-1-93 03:23:27

 

Rack1SW4#show vtp status 

VTP Version capable             : 1 to 3

VTP version running             : 2

VTP Domain Name                 : CCIE

VTP Pruning Mode                : Disabled

VTP Traps Generation            : Disabled

Device ID                       : 000f.2487.4700

Configuration last modified by 172.25.140.220 at 3-1-93 03:21:32

 

Feature VLAN:

--------------

VTP Operating Mode                : Client

Maximum VLANs supported locally   : 1005

Number of existing VLANs          : 16

Configuration Revision            : 10

MD5 digest                        : 0x45 0x38 0x3B 0xB5 0xFC 0x7D 0x89 0x43 

                                    0xBB 0x8D 0x53 0x77 0x60 0xBC 0xB7 0x90 

0

https://ieoc.com/discussion/18138/vtp-client-not-updating-from-vtp-server-when-vtp-transparent-node-inbetween